1 Croftbank Crescent
Uddingston
Glasgow G71 7JD
tel:01698 327997 - fax:01698 327776
(No1)
22mm
return flow
to boiler
(No2)
22mm
cold mains supply
(No3)
22mm
flow from boiler
(No4)
22mm
hot water
draw off
(No5)
pressure & temperature
relief valve
(No6)
integrated expansion vessel
(tornado models only)
(No7)
cylinder thermostat
(No8)
2.7kW
immersion heater
This diagram of the Tornado Stainless indirect unvented cylinder is for illustration purposes only. Thermsaver make every effort to ensure that the information given on this page is accurate, however this information may change as a result of continuing product research and development.
The Tornado Stainless has an integrated expansion vessel.
The Tempest Stainless has a separate expansion vessel to reduce the height of the unit.
If you place your mouse over the selector number on the unvented cylinder diagram the relevant description will appear to the left, under the "TECHNICAL DATA" heading.
The pressure reducing valve, which reduces the pressure to 3.0 bar, is factory set, as is the expansion valve which is pre-set to 5.0 bar.
| Model | Heat Up Time Cold - 65°C mins |
Re-Heat Time after 70% Draw Off mins |
| 125 | 36 | 25 |
| 150 | 37 | 26 |
| 170 | 36 | 25 |
| 200 | 33 | 24 |
| 250 | 35 | 25 |
| 300 | 40 | 29 |
| Assumes a cold water temperature of 15°C | ||
Please use our Enquiry Form if you have any unanswered questions or for any further information you may require.