Distributors of Heating, Hot Water and Ventilating Products - Established 1985

Call 01698 300100
For Sales or Technical Queries

FREE DELIVERY on all Orders


Search Site

Category Navigation:

You are currently on:

ACV Smartline SLE Plus 7 210ltr Indirect Stainless Steel Unvented Cylinder

Double click on above image to view full picture

Zoom Out
Zoom In

ACV Smartline SLE Plus 7 210ltr Indirect Stainless Steel Unvented Cylinder

Be the first to review this product

Excl. VAT: £ 920.00 Incl. VAT: £ 1,104.00

Useful Downloads
Brochure
Installation, Operation and Servicing Instruction
Add Items to Basket
OR

Quick Overview

ACV Smartline SLE Plus 7 210ltr Indirect Stainless Steel Unvented Cylinder including Thermostatic Mixing Valve and Mains Kit.

Fast Recovery Tank in Tank Cylinder, Perfect Partner to a Condensing Boiler.

Product Description

ACV Smartline SLE Plus 7 210ltr Indirect Stainless Steel Unvented Cylinder including Thermostatic Mixing Valve and Mains Kit.

The incredible heating surface area of the SmartLine stainless steel cylinder can take as much heat as a domestic condensing boiler can give it. This means the boiler will work in condensing mode for much longer than if it was working with a conventional coil cylinder,
therefore giving greater fuel efficiency.

High Outputs – Fast Recovery
At a time when consumers are demanding ever higher performance from their hot water installations, the traditional coil-based cylinder is often hard-pressed to keep up with demand. ACV Tank-in-Tank technology represents a significant advance in the science of hot water storage... so much so that, in virtually every situation encountered, the coil-based cylinder is completely out-classed.

Tank-In-Tank Technology
ACV’s advanced implementation of thermal storage technology is tried and tested and is remarkably simple, efficient and reliable. An inner stainless steel hot water cylinder is heated by primary water circulating through a surrounding outer tank connected to the boiler in the usual way. A much larger heat transfer surface means that Tank-in-Tank units recover much faster than any other kind of hot water storage device - and keeps boiler cycling to a minimum.

Resistance to Scaling
The special design of the inner cylinder not only helps ensure scale-free operation but also avoids the sediment problems that plague conventional cylinders.

* Total capacity 203ltr
* Primary Capacity 77ltr
* Heating area 1.54m2
* Pressure drop 37mbar
* Primary flow rate 3500ltr/hr
* Max useable input from boiler 39kw

* Preformance Data
Peak flow at 40degc in first 10 minutes 406ltr
Peak flow at 60degc in first 10 minutes 209ltr
Peak flow at 40degc in first hour 1349ltr
Peak flow at 60degc in first hour 689ltr
Continuous flow at 40degc 1527ltr/hr
Continuous flow at 60degc 576ltr/hr
Heat up time from 10 to 85degc 20 minutes