The ThermSave TH-0471 and QE2 central heating programmers are designed as replacements for practically all existing programmers.

The ThermSave TH-0471 has 42 individual selections/channel, (heating and hot water), with individual days or 5 day / 2 day groups selectable.

The QE2 can be set electronically for 24hr, 7 day, 5 day / 2 day operation.

Both are switchable between fully pumped and gravity systems.


universal back-plate
simple installation on to other manufacturers wall bases

Most programmers have very similar dimensions. A large proportion of those on the market today will fit directly onto the original Landis & Gyr RWB2 (Glow-Worm Mastermind & Potterton Miniminder) wall base. This has become adopted and is often referred to as the industry standard.

The ThermSave TH-0471 and Towerchron QE2 will fit directly onto the wall bases of all the programmers highlighted in the chart below - however to maintain good electrical contacts it is recommended that all wall bases be replaced when renewing programmers.


  wiring connection chart
manufacturer product
reference
earth neutral live compatible
terminal
numbers
programmer
links
Celect TH-0471 E N L 4 3 2 1  
Towerchron QE2/DP72 E N L 4 3 2 1  
  T2002 E N L CH HW      
  T2000 & T2003 E N L CH on HW on CH off HW off L-C-C-
ACL Drayton LP112/241/5/722 E N L 4 3 2 1  
  TEMPUS 3/4/7 E N L 4 3 2 1  
Glow-Worm MASTERMIND E N L 4 3 2 1  
Honeywell ST 6200/6300/6400 E N L 4 3 2 1  
  ST 6200A E N L 4 3 2 1  
  ST 7000 E N L 4 3 2 1  
  ST 699 E N L 3 6   7 L-5-8
  ST 7100 E N L 5 8   7 L-3-6
Horstmann 425/525/527/582 E N L 4 1   3 L-2-5
  C21 Centaurplus E N L 4 3 2 1  
Landis & Gyr RWB Range E N L 4 3 2 1  
Landis & Staefa RWB 2 E N L 4 3 2 1  
Potterton MINIMINDER E N L 4 3 2 1  
  MINIMINDER "E" E N L 4 3 2 1  
  EP 2001/3000/6000 E N L 4 3   1 L-5,N-N
Randall 102 & "E" 5 6 2 1     6-Mar
  3060/3020P E 7 6 2 4      
  4033 E 7 6 2 4   5 6-Jan
Danfoss Randall FP715 E N L 4 3 2 1  
Sunvic SP50 & 100 E N L 5 2   1 L-6
  SELECT 207 E N L 4 3 2 1  
Switchmaster 400 & 600 N L 1 3      
  805/900/9000/1   N L 1 3   4  
Myson MICROTIMER N L 3 6   7 L-5-8