heating zones and controls
heating zones and controls


add this page to your favourites add to favourites

remember

the building regulations now apply every time you change a boiler or hot water vessel!

more information?


We recommend that you check all your heating controls to maximise the overall efficiency of your complete system.

Effective control does bring further savings.

Thermsaver accept all major credit/debit cards.

NO SURCHARGE
on credit card purchases!

energy savings from programmable thermostats

The efficiency of a heating system is greatly increased by dividing the home into distinct heating zones covering different heating needs. In most cases there is no need to heat bedrooms during the day, when they are not in use, or to run the whole system at the same temperature.

Zoning is especially useful where unique time and temperature control of a part of the dwelling is required, such as for a granny flat, home, office or conservatory.

a zoned heating system can be made even more efficient by controlling boiler firing

The latest Building Regulations Part L1 specifies that in new houses with a total heated living space floor area of over 150m2 the heating circuit must be split into two, fully controlled, separate zones along with the fully controlled hot water zone.

Three zone system:
two heating and one domestic hot water.
The QE1 specifications are here The CM67 Specifications are here The thermsave celect digital programmable thermostat specifications are here The thermsave celect digital programmable thermostat specifications are here
home heating zone layout

Each zone should have its own independent time and temperature control and each zone can fire the boiler independently. The first zone to require heat switches the boiler on and the last zone to reach the preset temperature switches it off.

Thermsaver have a range of programmable room thermostats available - the ThermSave Celect LCD-RF-3, the ThermSave Celect LCD-3, the Honeywell CM67, the ThermSave Celect and the Towerstat RSP to meet these requirements.

In the Building Regulations this is referred to as Full Zoning, as it provides a boiler interlock - when there is no call for heat from any zone, the boiler is off.

For a new house with a total living space floor area of between 50m2 and 150m2, the installation must have more than one heating circuit zone, generally separating the sleeping from the living areas but, while the greatest efficiencies will be achieved by timing the second zone independently of the first, timing is optional in a house of this size.

For more information on gaining greater control of the heating zones got to our full featured control information page.

thermsaver - the company to rely on with the products you simply fit and forget