This example shows an actual layout plan of our heat recovery ventilation system in a single level dwelling.
The components used for this installation are listed below, (prices correct at 01/07/2007):
| Description | Qty | Each ex VAT |
Total ex VAT |
| System 325L Loft mounted air unit includes sonic/thermal insulation pack, control unit and condensate drain kit |
1 | 940.00 | 940.00 |
| Air grille with control kit - 100mm | 7 | 12.40 | 84.80 |
| Fire damper (fusible link) - 100mm | 1 | 44.50 | 44.50 |
| Fixed louvre outlet - 125mm | 2 | 9.60 | 19.20 |
| Aluminium duct (4m length) - 100mm | 7 | 12.90 | 90.30 |
| Aluminium duct (4m length) - 125mm | 4 | 15.80 | 63.20 |
| Tee - 125mm x 100mm | 5 | 20.50 | 102.50 |
| Male coupling - 100mm | 2 | 3.40 | 6.80 |
| Male coupling - 125mm | 1 | 3.80 | 3.80 |
| Reducer - 125mm x 100mm | 2 | 12.00 | 24.00 |
| Flexible silencer (1m) - 125mm | 2 | 87.10 | 174.20 |
| PVC sealing tape (33m) - 50mm | 3 | 15.10 | 45.30 |
| Wire fixing clips - 125mm | 4 | 1.30 | 5.20 |
| Total | 1603.80 |
| Less 25% internet discount | 400.95 |
| System cost (ex vat) | 1202.85 |
| System cost (inc vat) | 1413.34 |
We hope that this example illustrates the benefits of allowing thermsaver to design the heat recovery ventilation system using a set of plans to accurately compile a quotation.