This example shows an actual layout plan of our heat recovery ventilation system in a two floor dwelling.

The heat recovery ventilation design layout plan for the top floor of a two storey dwelling The heat recovery ventilation design layout plan for the ground floor of a two storey dwelling

The components used for this installation are listed below:

Component And Price List
Description Quantity
 Loft mounted air unit includes sonic/thermal insulation pack, control unit and condensate drain kit 1
Summer bypass unit with 230V elecric actuator 1
Air grille with control kit - 100mm 8
Air valve - 125mm 2
Air valve - 160mm 1
Fire damper (fusible link) - 100mm 1
Fixed louvre outlet - 160mm 2
Aluminium duct (4m length) - 100mm 6
Aluminium duct (4m length) - 125mm 7
Aluminium duct (4m length) - 160mm 8
Tee - 125mm x 100mm 3
Tee - 160mm x 100mm 3
Tee - 160mm x 125mm 2
Tee - 160mm x 160mm 1
Male coupling - 100mm 3
Male coupling - 125mm 5
Male coupling - 160mm 3
Reducer - 125mm x 100mm 2
Reducer - 160mm x 125mm 2
Flexible silencer (1m) - 160mm 2
PVC sealing tape (33m) - 50mm 5
Wire fixing clips - 160mm 4